The rules this app follows
Rulebook version 2026.11.23-1, sources read 23 Nov 2026. Every rule is quoted word for word from the source named under it.
Records a Victorian residential rental provider keeps to show a rental property met the rental minimum standards before it was advertised or offered for rent and before the renter moved in, and the gas, electrical and smoke alarm checks. Built only from the Consumer Affairs Victoria pages and the Victorian legislation listed in sources. Not for rooming houses, community housing or specialised housing programs.
The two moments
Before advertising or offering for rent
Keep a record showing the property met the rental minimum standards when you advertised it or offered it for rent. This duty is on the rental provider or their agent.
“(1) If a residential rental provider or the provider's agent advertises or otherwise offers premises to let, the provider or the provider's agent must keep records sufficient to demonstrate compliance with section 65B.”s. 65E(1), Residential Tenancies Act 1997 (Vic)
Before the renter moves in
Keep a record showing the property met the rental minimum standards on or before the day the renter moved in.
“(1) A residential rental provider must keep records sufficient to demonstrate compliance with section 65A.”s. 65C(1), Residential Tenancies Act 1997 (Vic)
Duties and penalties
Records are required from 13 October 2026
From 13 October 2026 every rental provider must keep these records.
“From 13 October 2026, all rental providers must keep records sufficient to show the property meets the rental minimum standards.”Introduction, Consumer Affairs Victoria: Rental properties - minimum standards
Show the move-in records when the Director asks
If the Director of Consumer Affairs Victoria asks, produce the move-in records as soon as practicable, in the way the Director asks. Maximum penalty: 150 penalty units for a person, 750 for a company.
“At the request of the Director, a residential rental provider must produce any records required to be kept under section 65C in the manner specified by the Director as soon as practicable after the request has been made. ... Penalty: 150 penalty units in the case of a natural person; ... 750 penalty units in the case of a body corporate.”s. 65D, Residential Tenancies Act 1997 (Vic)
Show the advertising records when the Director asks
If the Director asks, the rental provider or agent must produce the advertising records as soon as practicable, in the way the Director asks. Maximum penalty: 150 penalty units for a person, 750 for a company.
“At the request of the Director, a residential rental provider or the provider's agent must produce any records required to be kept under section 65E in the manner specified by the Director as soon as practicable after the request has been made. Penalty: 150 penalty units in the case of a natural person; 750 penalty units in the case of a body corporate.”s. 65F, Residential Tenancies Act 1997 (Vic)
The standards must be met by move-in day
The property must meet the rental minimum standards on or before the day the renter moves in. Maximum penalty: 60 penalty units for a person, 300 for a company.
“a residential rental provider must ensure that rented premises comply with prescribed rental minimum standards on or before the day on which the renter enters into occupation of the premises. Penalty: 60 penalty units in the case of a natural person; 300 penalty units in the case of a body corporate.”s. 65A(1), Residential Tenancies Act 1997 (Vic)
Advertise only with a reasonable belief the standards are met
Do not advertise or offer the property for rent unless, at that time, you reasonably believe it meets the rental minimum standards. Maximum penalty: 60 penalty units for a person, 300 for a company.
“A rental provider or the provider's agent must not advertise or otherwise offer premises to let unless at the time the premises are advertised or otherwise offered to let, the residential rental provider or the provider's agent reasonably believes the premises comply with the rental minimum standards | 60 penalty units for a person, 300 penalty units for body corporate”s.65B row, Consumer Affairs Victoria: Penalties - renting
Value of a penalty unit
A penalty unit is $209.10 in 2026-27. So 150 penalty units is $31,365 and 750 is $156,825; 60 is $12,546 and 300 is $62,730. These are maximums a court can set.
“The value of a penalty unit is $209.10 for financial year 2026-27.”Introduction, Consumer Affairs Victoria: Penalties - renting
The minimum standards
1. Bathroom
A bathroom with a washbasin and a shower or bath, connected to a reasonable supply of hot and cold water. Any shower head has a 3-star water rating, or 1 or 2 stars if a 3-star one can't be installed or wouldn't work with the plumbing (agreements made before 1 March 2027).
“In relation to bathroom facilities, the following amenities are to be provided in the rented premises--(a) a bathroom connected to a reasonable supply of hot and cold water that contains a washbasin and a shower or bath; (b) for rented premises let under a residential rental agreement entered into or created before 1 March 2027, if a shower is present--(i) a shower head with a 3 star rating in the rating system referred to in regulation 23(1)(a); or (ii) a shower head with a one or 2 star rating if a shower head with a 3 star rating--(A) cannot be installed; or ... (B) if installed, will not operate effectively due to the age, nature or structure of the plumbing of the premises.”Schedule 4, clause 4, Residential Tenancies Regulations 2021 (Vic)
2. Electrical safety
All power outlets and lighting circuits are connected to a switchboard-type circuit breaker and a switchboard-type safety switch (residual current device).
“On and from 29 March 2023, in relation to electrical safety, all power outlets and lighting circuits in the rented premises are to be connected to--(a) a switchboard-type Circuit Breaker that complies with AS/NZS 3000, "Electrical Installations", as published from time to time; and (b) a switchboard-type Residual Current Device that complies with--”Schedule 4, clause 9, Residential Tenancies Regulations 2021 (Vic)
3. Heating
A fixed heater in good working order in the main living area. In a house (a Class 1 building) it must be energy efficient. In an apartment (a Class 2 building) it must be energy efficient unless that would be unreasonable, and then any fixed heater in good working order. Energy efficient means a 2-star or better air conditioner, heat pump or gas space heater, ducted or hydronic heating with an outlet in the main living area, or a solid fuel heater such as a wood stove. The rule changes on 1 March 2027.
“(3) On and from 1 July 2025 until 28 February 2027, in relation to heating in a Class 1 building, an energy efficient fixed heater in good working order is to be installed in the main living area of the rented premises. (4) On and from 1 July 2025 until 28 February 2027, in relation to heating in a Class 2 building--(a) an energy efficient fixed heater in good working order is to be installed in the main living area of the rented premises unless it is unreasonable to install an energy efficient fixed heater; or (b) if it is unreasonable to install an energy efficient fixed heater in the main living area of the rented premises, a fixed heater in good working order is to be installed in the main living area of the rented premises.”Schedule 4, clause 14(3) and (4), Residential Tenancies Regulations 2021 (Vic)
4. Kitchen
A dedicated cooking and food preparation area, a sink in good working order with a reasonable supply of hot and cold water, and a cooktop in good working order with 2 or more burners. Any oven must be in good working order. (A registered heritage place refused a permit to alter is exempt from the first part.)
“(a) a dedicated area which is intended to be used for cooking and food preparation; (b) a sink in good working order that is connected to a reasonable supply of hot and cold water; (c) a cooktop in good working order that has 2 or more burners. ... (3) Any oven at the rented premises must be in good working order.”Schedule 4, clause 5, Residential Tenancies Regulations 2021 (Vic)
5. Laundry
If there is a laundry, it is connected to a reasonable supply of hot and cold water.
“Any laundry facilities present in the rented premises must be connected to a reasonable supply of hot and cold water.”Schedule 4, clause 6, Residential Tenancies Regulations 2021 (Vic)
6. Lightingunclear
Inside rooms, corridors and hallways have light suited to how they are used. Each habitable room has natural light by day (light from a next-door room counts) and artificial light at night. (A registered heritage place refused a permit to alter is exempt.)
The regulation asks for light "appropriate to the function or use" of each room but gives no level, so the sources don't say what would show it. A dated photo of each room with the lights on is a reasonable record, but that is this app's suggestion, not the regulator's.
“(1) The interior rooms, corridors and hallways of the rented premises are to have access to light, whether natural or artificial, which provides a level of illuminance appropriate to the function or use of those rooms. (2) Each habitable room of the rented premises is to have access to--(a) natural light, including borrowed light from an adjoining room, during daylight hours, which provides a level of illuminance appropriate to the function or use of the room; and (b) artificial light during non-daylight hours which provides a level of illuminance appropriate to the function or use of the room.”Schedule 4, clause 12, Residential Tenancies Regulations 2021 (Vic)
7. Locks
Every external entry door that can't be secured with a working deadlock (other than a screen door) has at least a lock that is worked by a key from outside and can be unlocked from inside, with or without a key. Not for a public lobby door onto common property, or a registered heritage place refused a permit to alter.
“(1) All external entry doors to the rented premises which are not able to be secured with a functioning deadlock, other than any screen door attached to an external door, must at least be fitted with a locking device that--(a) is operated by a key from the outside; and (b) may be unlocked from the inside with or without a key.”Schedule 4, clause 1, Residential Tenancies Regulations 2021 (Vic)
8. Mould and damp
Every room is free from mould and damp caused by or related to the building structure.
“Each room in the rented premises must be free from mould and damp caused by or related to the building structure.”Schedule 4, clause 8, Residential Tenancies Regulations 2021 (Vic)
9. Structural soundness
The property is structurally sound and weatherproof.
“The rented premises are to be structurally sound and weatherproof.”Schedule 4, clause 7, Residential Tenancies Regulations 2021 (Vic)
10. Toilets
A toilet in good working order, connected to the sewer, an onsite wastewater system managed under the guidelines, or another system accepted by the local council, and in a room or separate enclosed structure meant to be used as a toilet area.
“The rented premises are to contain a toilet that is--(a) in good working order, connected to--(i) a reticulated sewerage system; or ... (iii) any other system approved by the local council; and (b) either in--(i) a room that is intended to be used as a toilet area, whether as a separate toilet or bathroom or combined bathroom and laundry; or (ii) a separate enclosed structure that is intended to be used as a toilet area.”Schedule 4, clause 3, Residential Tenancies Regulations 2021 (Vic)
11. Ventilationunclear
Each habitable room, bathroom, shower room, toilet and laundry has ventilation that satisfies the 2019 Building Code of Australia (Volume Two for a house, Volume One for an apartment).
The standard is set by reference to performance requirements in the 2019 Building Code of Australia, which a landlord can't check by eye, and the sources don't say what record would show it. A builder's or plumber's note, or photos of the windows, vents and exhaust fans, are this app's suggestions only.
“(1) If the rented premises is a Class 1 building, each habitable room, bathroom, shower room, toilet and laundry must have ventilation satisfying Performance Requirement P2.4.5 of the 2019 Building Code of Australia Volume Two, or the Acceptable Construction Practice in Part 3.8.5 of the 2019 Building Code of Australia Volume Two.”Schedule 4, clause 13, Residential Tenancies Regulations 2021 (Vic)
12. Vermin-proof bins
A rubbish bin and a recycling bin for the renter, either from the council or vermin proof and compatible with council collection.
“A rubbish bin and a recycling bin are to be supplied for use by the renter of the rented premises which are--(a) provided by the local council; or (b) vermin proof and compatible with local council collection.”Schedule 4, clause 2, Residential Tenancies Regulations 2021 (Vic)
13. Windows
Every external window that opens can be set open or closed, and has a working latch that secures it against entry from outside. A window lock or bolt counts.
“(1) All external windows in the rented premises that are capable of opening must be able to be set in a closed or open position. (2) All external windows in the rented premises which are capable of opening must have a functioning latch to secure the windows against external entry. Note A window lock or bolt will meet the minimum standard referred to in subclause (2).”Schedule 4, clause 11, Residential Tenancies Regulations 2021 (Vic)
14. Window coverings
Each window in a room likely to be a bedroom or living area has a curtain or blind the renter can open and close, that reasonably blocks light and gives reasonable privacy.
“On and from 29 March 2022, each window in a room at the rented premises that is likely to be used as a bedroom or as a living area is to be fitted with a curtain or blind that can be opened or closed by the renter to--(a) reasonably block light; and (b) provide reasonable privacy to the renter.”Schedule 4, clause 10, Residential Tenancies Regulations 2021 (Vic)
15. Window covering anchors
From 1 December 2025, any corded internal blind or curtain is set up so a loose cord can't form a loop of 220 mm or longer less than 1600 mm above the floor. The cord is held by a cord guide (mounted to take 70 newtons for 10 seconds if it is lower than 1600 mm) or by a cleat at least 1600 mm up, installed as the covering's instructions say.
“On and from 1 December 2025, the standard for corded internal window coverings installed at the rented premises is that--(a) a loose cord that is part of the window covering cannot form a loop of 220 mm or longer that is less than 1600 mm above floor level, and is secured by either--(i) a cord guide, no part of which is installed lower than 1600 mm above floor level, unless--(A) the cord guide will remain firmly attached to a wall or other structure specified in the installation instructions for the corded internal window covering when subjected to a tension force of 70 Newtons applied in any direction for 10 seconds; and (B) the cord is sufficiently secured or tensioned to prevent the formation of a loop 220 mm or longer; or (ii) a cleat that is installed against a wall or structure at least 1600 mm above floor level; and”Schedule 4, clause 15, Residential Tenancies Regulations 2021 (Vic)
Safety checks
Electrical safety check
Have a licensed or registered electrician check all electrical installations, appliances and fittings you provide, every 2 years. Keep the record until the next one is made. Give the renter a copy within 7 days of a written request.
“The residential rental provider must ensure that an electrical safety check of all electrical installations, appliances and fittings provided by a residential rental provider in the rented premises is conducted every 2 years by a licensed or registered electrician”Schedule 3, clause 1(1), Residential Tenancies Regulations 2021 (Vic)
Gas safety check
If the property has gas appliances, fixtures or fittings, have a licensed or registered gasfitter check all gas installations and fittings every 2 years. Keep the record until the next one is made. Give the renter a copy within 7 days of a written request.
“(1) The safety-related activities in subclauses (2) and (3) only apply if the rented premises contain any appliances, fixtures or fittings which use or supply gas. (2) The residential rental provider must ensure that a gas safety check of all gas installations and fittings in the rented premises is conducted every 2 years by a licensed or registered gasfitter”Schedule 3, clause 2(1) and (2), Residential Tenancies Regulations 2021 (Vic)
Smoke alarm test
Make sure every smoke alarm is correctly installed, working and has batteries, and is tested at least once every 12 months following the maker's instructions. A mains-powered alarm must be tested by a suitably qualified person.
“(c) tested at least once every 12 months in accordance with any instructions by the manufacturer of the smoke alarm.”s. 68AA(2)(c), Residential Tenancies Act 1997 (Vic)
Unclear in the sources
What counts as a "sufficient" record of the minimum standards
“(2) The Director may publish a notice that sets out guidance about what records are sufficient to demonstrate compliance with section 65A.”s. 65C(2), Residential Tenancies Act 1997 (Vic)
“(2) The Director may publish a notice that sets out guidance about what records are sufficient to demonstrate compliance with section 65B.”s. 65E(2), Residential Tenancies Act 1997 (Vic)
No such notice was found on 23 November 2026 (Consumer Affairs Victoria pages and a web search). The app asks for at least one dated photo, document or note for each standard, and calls a record "complete" when every standard and safety check has one. That is the app's own bar, not the Director's. When a notice is published, re-read it and update this rulebook.
What a minimum standards record must contain
“Rental providers or their agents must keep records that show the property met the minimum rental standards before the property was advertised, offered, or the renter moved in.”Records showing compliance with the rental minimum standards, Consumer Affairs Victoria: New changes to rental laws
Neither the Act nor the regulations prescribe the contents (unlike gas and electrical check records, reg. 30). The pack holds the property, the moment, the date, each standard with its dated evidence, the safety checks and the rulebook version.
How long minimum standards records must be kept
“(1) A residential rental provider must keep records sufficient to demonstrate compliance with section 65A.”s. 65C(1), Residential Tenancies Act 1997 (Vic)
Sections 65C to 65F set no period. The app keeps records until the user deletes them, and never deletes on a schedule. Gas and electrical check records have a set period: until the next check's record is made (reg. 30).
Penalty for not keeping the records
“Penalty: 150 penalty units in the case of a natural person;”s. 65D, Residential Tenancies Act 1997 (Vic)
Sections 65C and 65E (keep records) carry no penalty of their own in the Act's text. Sections 65D and 65F (produce them when the Director asks) do: 150 penalty units for a person, 750 for a company. Whether failing to keep a record is dealt with as failing to produce it is not stated.
"Before" or "at the time" of advertising
“before the property was advertised or offered for rent”Record keeping for minimum standards, Consumer Affairs Victoria: Rental properties - minimum standards
“unless at the time the premises are advertised or otherwise offered to let, the residential rental provider or the provider's agent reasonably believes the premises comply with the rental minimum standards.”s. 65B, Residential Tenancies Act 1997 (Vic)
The Act's test is a reasonable belief at the time of advertising. The app asks for the date the property was (or will be) advertised and shows evidence dated after it as a gap.
Records of smoke alarm tests
“From 25 November 2025, it will be mandatory for all rental properties to have annual smoke alarm safety checks to ensure they are correctly installed and in working condition.”From 25 November 2025, Consumer Affairs Victoria: Smoke alarms and fire safety
The sources require the test every 12 months but set no record-keeping rule for it, unlike gas and electrical checks. The app records the test like the other checks anyway, because without a record the test can't be shown.
Lighting standard has no measurable level
“which provides a level of illuminance appropriate to the function or use of those rooms.”Schedule 4, clause 12, Residential Tenancies Regulations 2021 (Vic)
Marked unclear on the standard; the app asks for a record like any other standard.
Ventilation standard refers to the Building Code
“must have ventilation satisfying Performance Requirement P2.4.5 of the 2019 Building Code of Australia Volume Two”Schedule 4, clause 13, Residential Tenancies Regulations 2021 (Vic)
Marked unclear on the standard; the app asks for a record like any other standard.
The regulation and the CAV page word the lock standard differently
“(b) may be unlocked from the inside with or without a key.”Schedule 4, clause 1, Residential Tenancies Regulations 2021 (Vic)
“can be unlocked without one from the inside.”Locks, Consumer Affairs Victoria: Rental properties - minimum standards
The app shows the regulation's words.
Name of the electrical inspection standard
“carried out in accordance with section 4 of AS/NZS 3019 "Electrical installations-- Periodic assessment"”s. 3(1), electrical safety check, Residential Tenancies Act 1997 (Vic)
“a report prepared in accordance with section 2 of AS/NZS 3019, "Electrical installations--Periodic verification"”reg. 30(2)(a)(v), Residential Tenancies Regulations 2021 (Vic)
The Act and the regulations give AS/NZS 3019 different titles. The app asks for "the electrician's report (AS/NZS 3019)" without a title.
Not covered
- Rooming houses, community housing and specialised housing programs. They have their own standards (Schedule 6 and the rooming house rules). This version covers ordinary residential rental agreements only.
- Cooling (Schedule 4, clause 16) and the minimum energy efficiency standards. They start on 1 March 2027. Add them to the rulebook before then.
- Pre-draughtproofing gas check (s. 68C). Only needed before draughtproofing work; a separate check from the 2-yearly one.
- Swimming pool barriers and bushfire water tanks (Schedule 3, clauses 4 to 6). Only some properties; not part of the minimum standards record.
- Written smoke alarm information for the renter at the start of an agreement. A duty at the start of the agreement, not a property standard.
- The rest of the pre-agreement disclosure (reg. 16). The app shows only the gas and electrical check dates and outstanding recommendations, which the record already holds.
Sources
- Residential Tenancies Act 1997 (Vic), Authorised version No. 115, in force from 13 October 2026 (extract: s. 3(1) definitions of gas and electrical safety check; ss. 65A to 68C). Read 23 Nov 2026.
- Residential Tenancies Regulations 2021 (Vic), Authorised version No. 009, in force from 30 June 2026 (extract: regs 16, 29, 30; Schedules 3 and 4). Read 23 Nov 2026.
- Consumer Affairs Victoria: Rental properties - minimum standards, Web page, last updated 14 October 2026. Read 23 Nov 2026.
- Consumer Affairs Victoria: New changes to rental laws, Web page. Read 23 Nov 2026.
- Consumer Affairs Victoria: Rental providers - gas and electrical safety, Web page. Read 23 Nov 2026.
- Consumer Affairs Victoria: Smoke alarms and fire safety, Web page. Read 23 Nov 2026.
- Consumer Affairs Victoria: Rental minimum standards checklist for rental providers, PDF, 2 pages. Read 23 Nov 2026.
- Consumer Affairs Victoria: Penalties - renting, Web page, last updated 14 October 2026. Read 23 Nov 2026.
This is the rental provider's own record. It is not legal advice. Consumer Affairs Victoria decides whether a property meets the rental minimum standards.